Battery Doctor 20085 Benutzerhandbuch - Seite 6
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Batterieladegerät Battery Doctor 20085 herunter. Battery Doctor 20085 6 Seiten. Automatic switching mode with micro-controlled input: 100-140 vac / output: 12volt dc
Note: The Charger automatically switches off after 24 hours if the Bulk charge cycle is not completed.
CHARGER SPECIFICATIONS
1. Input: 100~140Vac; 60Hz;
2. Charging starting conditions: Battery is not less than 3V
3. Rated output: 13.5V at 2/4/8A selectable on SW121080,
4. Type of Lead-acid Battery: Gel/AGM&WET/Calcium
5. Charging output voltage (Absorption): 14.1/14.4/14.7V at Gel/AGM&WET/Calcium
6. Charging output voltage (Automatic Equalisation): 16.2V only for Calcium battery
7. Float output voltage: 13.4/13.5/13.6V at Gel/AGM&WET/Calcium
8. Operating Environmental: 0~40 degC, 90% RH maximum; non-Condensing
9. Net Weight: 860g approx (SW121080)
10. Dimension: L192 x W95 x H55mm (SW121080)
TROUBLE SHOOTING
Problems
Indication
Charger does
Indicator lights are not
not work
on
Charger has
Fault LED is ON.
no DC output
No Charging
Fault LED is Flashing
Current
Long charging
time, Full light
Fault LED is Flashing
does not come
on
Abnormal LED
ALL LED's Flashing
indication
Possible causes
- No AC power
- Output is short circuited
- Output Reverse polarity connection
- Battery is severely sulphated
- Battery has a damaged cell
- Charger overhead protection mode
- Wrong battery type selected
- Battery capacity too large
- Battery is defective
- 6 hours soft start timer reached
- 24 hours bulk charge timer reached
- Poor connection from Charger to
Battery
-
6-
Suggest solution
- Check AC connections and make
sure Power Point is switched ON
- Check DC connection between charger
and battery and make sure they are not
short circuiting.
- Check that the alligator clips / ring
terminals are connected to the correct
polarity.
- Check the Battery condition, age etc.
- If battery cannot be rejuvenated it must
be replaced.
- Move battery & Charger to cooler
environment
- Check the charging rate and battery type
selection matches the battery.
- Battery cannot be charged and must
be replaced.
- Check for a loose battery terminal
connection.
- Check the output wires alligator clips
for loose / damaged connection.