Operating the Charger
Once correctly installed the Battery Link DC-DC charger is a simple set and forget dual battery
switch.
• Start the vehicle and let it idle.
• The charger will now recognize that there is charge being applied to the main starting battery.
• Once the main starting battery has reached 12.8 volts the charger will automatically turn on.
• Once the voltage reaches 13.4 volts the charger will begin to charge the auxiliary battery.
• The initial default setting is for lead acid batteries.
• If you are charging a battery with a different chemistry simply change the battery type by pressing
the battery type selector button on the front of the charger.
• Once selected, the charger will remain on this battery type until it is changed.
• The charger will continue to operate even after the vehicle has been switched off, however once the
main starting battery falls below 12.5 volts the charger will automatically shut off.