BatteryMINDer 244CEC1 Schnellstart-Handbuch - Seite 8

Blättern Sie online oder laden Sie pdf Schnellstart-Handbuch für Batterieladegerät BatteryMINDer 244CEC1 herunter. BatteryMINDer 244CEC1 12 Seiten. Battery maintainer-desulfators

BatteryMINDer
Load Light OFF
Soft-Start
Constant
Current
Constant
Voltage
Float
(Charge
Complete)
Load Light ON
Float
(Battery < 11V)
Float
(Battery < 12V)
Float
(Battery < 13V)
Float
(Battery < 13V)
Rev. A2-010516
®
VDC 128CEC1 LABEL
128CEC1
8A Setting
4A Setting
2A Setting
8A
4A
2A
14.1 (Gel)
14.4 (Wet, AGM, Sealed)
14.7 (Odyssey, PLT)
13.05 (Gel)
13.4 (Wet, AGM, Sealed)
13.6 (Odyssey, PLT)
8A
4A
2A
8A
4A
2A
8A
4A
2A
8A
4A
2A
4A
Soft-Start
2A
1A
Constant
Current
Constant
Voltage
Float
(Charge
Complete)
Float
(Battery < 22V)
Float
(Battery < 24V)
Float
(Battery < 26V)
Float
(Battery < 26V)
Page 8
Models 128CEC1 & 244CEC1
For
244CEC1
model,
please
refer to
actual unit
244CEC1
Load Light OFF
4A Setting
2A Setting
1A Setting
4A
2A
1A
28.2 (Gel)
28.8 (Wet, AGM, Sealed)
29.4 (Odyssey, PLT)
26.1 (Gel)
26.8 (Wet, AGM, Sealed)
27.2 (Odyssey, PLT)
Load Light ON
4A
2A
1A
4A
2A
1A
4A
2A
1A
4A
2A
1A
P/N VDC128/244-CEC1-QSS
2A
1A
.5A