EGLOW PROBLEM SOLVING continued
Connect each pod in turn.
Does any one pod, when
connected, turn off the boiler?
Yes
Notes
LED layout
Diagram
Green: ON
Red: off but board powered
Fault: Red Cont= Flow
Red Flash= Overheat
Mode
Central hea ng
Under floor
3KW
6KW
9KW
12KW
Enable main contactor
Disable main contactor
X = Any posi on
TO CHECK INDIVIDUAL PODS MAKE SURE THERE IS CONTINUITY ACROSS THE TERMINALS AND
THAT THE RESISTANCE IS 21 OHMS
Pump
SW1
SW2
Off
X
On
X
X
Off
X
Off
X
On
X
On
X
X
X
X
11
Replace pod
Pods 1 to 4
SW3
X
X
Off
On
Off
On
X
X
3
SW4
X
X
X
X
X
X
On
Off