6 - DUST INLET PIPE REVERSIBILITY
The dust-rich airfl ow inlet pipe can be installed to the right or to the left of the separator, by a simple
operation described in fi gures 1-2-3
1
2
3
7 - PIPE INSTALLATION AND CONNECTION
The separator must be fastened to a wall or to another fi rm support, using the preset and pre-drilled steel sheet
fastening fl anges.
Example wall fastening
When fastening the separator, take care to leave a gap of at least 100 mm between it and the ground, to be
able to remove and empty the dust bucket.
The airfl ow inlet and outlet pipes, which both have a diameter of 50 mm, must be connected using the two
supplied rubber sleeves; as an alternative, they can directly be connected through an antistatic hose; in both
cases, the supplied steel clamps shall be fi rmly tightened on the junctions.
8
(LINGUA ORIGINALE)
23/05/2022 Rev:1.0.0