2.7.2.5 New Tag Programming without PIN (05)

STEP 1 – Unit must be in Main Menu – as in " Enter Main Menu" – 2 Long Flashes
STEP2 – Enter 05 on the Keypad.
RESPONSE – Sound 5 Long and continue with 5 Short Flashes – Indicating in " New Tag
Programming" and waiting for next Tag.
STEP 3 – Present new Tag to Reader
RESPONSE - Sound 2 Short and continue with 5 Short Flashes – Indicating Tag accepted and
Programmed and waiting for next Tag.
Repeat STEP 3 for all Tags to be programmed
STEP 6 – Enter Escape (ESC) on the Keypad to return to Main Menu
RESPONSE – No Sound but Change to 2 Long Flashes – Indicating back into Main Menu.

2.7.2.6 Existing Tag Delete (06)

STEP 1 – Unit must be in Main Menu – as in " Enter Main Menu" – 2 Long Flashes
STEP 2 – Enter 06 on the Keypad.
RESPONSE – Sound 6 Long and continue with 6 Short Flashes – Indicating in " Tag Delete" and
waiting for Tag Serial Number to be entered.
STEP 3 – Enter 4 Digit Serial Number of Tag to be deleted.
STEP 4 – Enter Enter (ENT) on the Keypad.
RESPONSE – Sound 2 Short and continue with 6 Short Flashes – Indicating that Entered Tag has
been deleted and waiting for next 4 Digit Serial Number.
Repeat STEP 3 to 4 for all Tags to be deleted.
STEP 5 – Enter Escape (ESC) on the Keypad to return to Main Menu
RESPONSE – No Sound but Change to 2 Long Flashes – Indicating back into Main Menu

2.7.2.7 Access Criteria Programming (07)

STEP 1 - Unit must be in Main Menu – as in " Enter Main Menu" – 2 Long Flashes
STEP 2 – Enter 07 on the Keypad.
RESPONSE – Sound 7 Long and continue to 7 Short Flashes – Indicating in " Access Criteria" and
waiting for new Access Criteria Data.
STEP 3 – Enter one of the following on the Keypad:
RESPONSE – Sound 2 Short then Change to 2 Long Flashes – Indicating new Criteria is set and back
in Main Menu.

2.7.2.8 Set Lock Release Time (08)

STEP 1 - Unit must be in Main Menu – as in " Enter Main Menu" – 2 Long Flashes
STEP 2 – Enter 08 on the Keypad.
RESPONSE – Sound 8 Long and continue with 8 Short Flashes – Indicating in " Lock Release Time"
and waiting for new Time Data.
STEP 3 – Enter a 2 Digit value for the Lock Release Time (00 to 99)
RESPONSE – Sound 2 Short and then Change to 2 Long Flashes – Indicating new Lock Release Time
Applied and back in Main Menu.

2.7.2.9 Door Alarm Functions (09)

STEP 1 - Unit must be in Main Menu – as in " Enter Main Menu" – 2 Long Flashes
STEP 2 – Enter 09 on the Keypad.
RESPONSE – Sound 9 Long and continue with 9 Short Flashes – Indicating in " Door Alarm
Functions" and waiting for new Function Data.
STEP 3 – Enter one of the following:
STEP 4 – Enter 2 Digit Ajar Delay (00 to 99) before Reader Alarm Sounds.
STEP 5 – Enter one of the following:
STEP 6 – Enter 2 Digit Siren On Time (00 to 99)
Daffue Electronic Solutions cc –
0 – Card or Keypad or
1 – Card Only or
2 - Keypad Only or
3 – Card and Keypad
0 – Nothing happens if a door stays open or
1 – Only Reader Alarm Sounds when a door stays open
2 – Reader Alarm and then External Alarm Sounds when door stays open
0 – Nothing happens when the door is forced open
1 – External Alarm Sounds when door is forced open
MONOLOG Users Manual - Issue 1B