DOTECH FX3S Benutzerhandbuch
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Temperaturregler DOTECH FX3S herunter. DOTECH FX3S 4 Seiten. Digital temperature control
Digital Temperature Control
FX3S
User's Manual
DOTECH INC.
6F , JOONGANG-ILBO B/D, 30, Dongsan-ro, Danwon-gu, Ansan-si, Gyeonggi-do, KOREA
1. This product may cause an electric shock in handling. Please do not attempt to open it with power turned on.
2. This product should be installed in a place fixed secured by a rack or panel.
3. This product can be used under the following environmental condition. ① Indoor ② Pollution Degree 2 ③ At an altitude of 2000m or below
Cautions
4. Power input must be within the designated ranges.
5. To turn on or turn off power supply for this product, please the circuit breaker or switch of a standard product of IEC 60947-1 or IEC 60947-3 product
and install it within a close distance allowing convenient operation by user.
6. Please be understood that if this product is dismantled or modified discretionary, after sales service will not be able to be provided.
7 . An output wire to be used for this product should be inflammable grade FV1 (V-1 grade or above), the thickness of the wire should be AWG No. 20 or
2
above(0.50mm
).
8. In order to prevent it from an inductive noise, please maintain the high-voltage wire and power wire separated.
9. Please avoid installing the product in a place where a strong magnetism, noise, severe vibration and impact exist.
10. When extending the sensor wire, use a shield wire and do not extend it unnecessary long.
11. The sensor wire and signal wire should be away from the power and load wires using conduits separately installed.
12. Please avoid using the product near a device generating strong high frequency noise (high-frequency welding machine, high-frequency sewing
machine, high-frequency radiotelegraph, high capacity SCR controller)
13. Product's damages other than those decribed in the guarantee conditions provided by the manufacturer shall not be respoinsible by us.
14. If this unit is used to control machineries (Medical equipment, vehicle, train, airplane, combustion apparatus, entertainment, processing and
transportation equipment, elevator and various safety device etc.) enabling to effect on human or property, it is required to install fail-safe device.
※ The Aforementioned precautions must be observed, and if you fail to do so, it may cause a product's breakdown.
※ The specifications, dimensions, and etc. are subject to change for enhancement without a prior notice.
Technical Specifications
Power
100–240Vac, 50/60Hz
Current
MAX 6 VA
Connection
Screw Bolt Connector(1.5mm
Output
Relay Output 1 Point (250Vac/16A)
Input
Temp. Sensor Input 1 Point
Dimensions
78(W)mm X 35(H)mm X 78(D)mm
Operation
Temperature: -10 ~ 50°C, Humidity: Below 90%RH
Storage
Temperature: -20 ~ 60°C, Humidity: Below 90%RH
Components
Product
※ Specifications are subject to change without prior notice.
2
Wire Use Possibility)
User's Manual
Bracket 2ea
User's Manual
- Selection of Output(Heating/Cooling)
- Precise Temperature Control
- Sensor Calibration
- Sensor Error Detection
- Auto Save and Restoration of Parameter Values
- Minimum On/Off Duration Time Setup
- Minimum Duty Cycle Output Setup
Ordering guide
FX3S-00
Basic Model (220Vac)
FX3S-00-T
Basic Model (12Vdc)
FX3S-00-H
Basic Model (24/48Vdc)
Accessories
35
Ø5
SUS PIPE
DPR-TH01-ET : NTC 5 KΩ at 25 °C / -50~105 °C / ±0.3 °C at 25 °C
100
Ø6
DPR-TH02-P6D100L : NTC 10 KΩ at 25 °C / -50~150 °C / ±1.5 °C at 25 °C
- 1 -
ZH2014-11003
SHRINK TUBE
LEAD WIRE
SUS PIPE
SPRING PROTECT
LEAD WIRE
R20160721