Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Controller DOTECH EVC10B-00 herunter. DOTECH EVC10B-00 8 Seiten. Electronic expansion valve controller
: Accessory
Items
Description
Sensor type
Cable
Protection level
DPR-TH1-ST-XHP
Accuracy
Measuring range
6sq
24069001 : AC Power Transformer (30VA), 220Vac to 24Vac
24069001
Connection kit
2.
Installation
: Dimensions
※ It can be installed with rail or using screw (4 ea)
: Terminal
No.
Definition
J1
24 Vac
J2
RUN
J3
RS485
J4
AUX-RLY
J5
P-SENS
J6
T-SENS
J7
EEV
NTC 5KΩ
2 C X 0.5 mm
IP67
±0.3 ℃ at 25 ℃
-50 to 50 ℃
25mm
2m
Description
Control power input port (AC24V)
Run signal input port (RUN)
RS485 comm. Input / output port (RS485)
Auxiliary relay output port (AUX-RLY)
Pressure sensor input port (P-SENS)
Temperature sensor input port (T-SENS)
Electronic expansion valve output port (EEV MOTOR)
Items
Description
Sensor power
Signal output
Pressure
measure range
Operating
temperature
Protection level
Accuracy
DP512-G7-XHP
Stability
(-1~15bar)
Connector Type
Wiring
: Wiring Diagram
-2-
5 Vdc ±5 %
0.5 - 4.5 Vdc (Ratiometric)
-1 ~ 15 bar
-40 ~ 120 ℃
IP65
± 1.0 %
F.S
± 0. 5 % (Longterm Stability)
7/16" UNF / FEMALE
Black(com), Green(out), Red(+5v)
EVC10B R20140821