Doug Fleenor Design Preset 10 Architectural Benutzerhandbuch - Seite 4
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Kontrolleinheit Doug Fleenor Design Preset 10 Architectural herunter. Doug Fleenor Design Preset 10 Architectural 8 Seiten.
PRESET 10 ARCHITECTURAL – INSTALLATION
WIRING INFORMATION
The Preset 10 Architectural is designed to use daisy-chain wiring topology. An alternative to the daisy-
chain topology is the star topology. To create a star, a bidirectional isolated splitter (model 127) is
required. Also note that a system may contain multiple power supplies when voltage drop becomes a
concern. Please give us a call if you have any questions.
CABLE
120 Ohm Data Cable
1
Belden 9829 or
Equivalent
(2) #16 AWG
2
Stranded Wires
120 Ohm Data Cable
3
Belden 9829 or
Equivalent
(2) #16 AWG
4
Stranded Wires
120 Ohm Data Cable
5
Belden 9829 or
Equivalent
POWER SUPPLY
The voltage provided to the Preset 10 Architectural must be between 9 and 15 volts AC or DC, 200mA
per station. The Preset 10 Architectural has been designed to operate on a standard class 2 "doorbell"
transformer (e.g. Ace Hardware's model #ACE36483 10 volt 5 watt transformer).
COLOR
FROM
Shield
White/Blue
5 Pin XLR Plate
Stripe
Blue/White
Stripe
Black
Power Supply
Red
Shield
White/Blue
Stripe
Blue/White
PRE10 Main
Stripe
Black
Red
Shield
White/Blue
PRE10 Remote
Blue/White
Stripe
TO
Pin 1
Pin 2
Pin 3
PRE10 Main
Common
Power
TB1-1
TB1-2
TB1-3
PRE10 Remote
TB1-4
TB1-5
TB1-1
TB1-2
Dimmer Cabinet
TB1-3
Page 4 of 8
USE
TB1-1
Common
TB1-2
Data -
TB1-3
Data +
TB1-4
Supply
Supply "hot"
common
TB1-5
TB1-1
Common
TB1-2
Data -
TB1-3
Data +
TB1-4
Supply
Supply "hot"
common
TB1-5
?
Common
?
Data -
?
Data +