Problem
Possible Causes
Dehumidifier
The power cord is unplugged.
can not turn on
The fuse is blown or circuit breaker is tripped.
The water bucket is full or not in the proper
position.
The room humidity has reached the set-point
Dehumidifier is
and the dehumidifier enters into Standby
on, but it does
Mode where you can see the Mode icon (DH
not run.
or DRY) flickering.
The room humidity is lower than the set
humidity. In this case, you can see the Mode
icon (DH or DRY) flickering.
The dehumidifier is in the defrosting process.
Insufficient dehumidifying time.
The room has not been sealed properly.
Insufficient
The air filter is dirty.
dehumidifying
Airflow has been blocked.
Performance
There is something giving off water vapor in
the room.
The room temperature is low.
The dehumidifier size is too small for the
room.
Check if the dehumidifier is in CONTINOUS
MODE.
Dehumidifier
The room humidity is too high.
operates
continuously
Doors and windows are open.
The dehumidifier's not positioned level.
The water bucket is not in the proper
Noise
position.
The air filter is clogged.
The dehumidifier has been turned on
Frost appears
recently.
on the coils
Room temperature is close to or lower than
60°F.
Hose connection is loose.
Water leakage
Hose connection is loose.
Water does not
Water flow has been restricted.
drain from
the hose
Solutions
Plug it in.
Check the fuse or the circuit breaker.
Make sure the water bucket is empty and has
been installed properly.
Set a lower humidity or let the dehumidifier
keep in standby mode.
The set humidity needs to be at least 5%
(recommend 10%) lower than room humidity.
It is normal the compressor ceases during the
defrosting process.
When first installed, allow at least 3-4 days to
maintain the desired RH.
Ensure that all doors, windows and other
openings are closed.
Clean the air filter.
Ensure there are no obstructions block the
airflow.
Remove those items or turn off such devices
that give off vapor in the room.
Heat up the room.
Increase the quantity of dehumidifiers. Or
change a higher capacity dehumidifier.
Don't set the humidity too low. Typically,
40-50% are good settings to use.
Change humidity settings. Or change a higher
capacity dehumidifier.
Ensure that all doors, windows and other
openings are closed.
Position the dehumidifier on a level surface.
Re-install the water bucket properly.
Wash the filter.
This is normal frost builds up on the coils,
especially when the ambient temperature is
low. The dehumidifier will defrost
automatically.
Check the hose connection. Try to attach the
other end of the hose to the outlet.
Check the hose connection. Try to attach the
other end of the hose to the outlet.
Hoses more than 7 feet long may not drain
properly. It is recommended to keep the hose
as short as possible. The hose must be placed
lower than the bottom of the dehumidifier,
and be kept flat and smooth without kinks.
15