RERUN ARCHITECTURAL FACEPLATE CONFIGURATION
Each Rerun Architectural has six jumpers, JP1 through JP6, that select different modes of operation. The
factory default is to have all jumpers installed.
JP1
Record Lockout - When removed, the [RECORD] button is disabled. When installed, recording of
presets is enabled.
JP2
Hold Last Look - When removed, upon the loss of signal the last valid input is held on the output.
When installed, upon the loss of signal the last active show is started.
JP3
Hardware Test - Rerun Architectural enters a hardware test mode when this jumper is removed.
JP4
Leave installed. This jumper is only removed for factory use.
JP5
When installed, incoming DMX512 signals will override the Rerun Architectural levels and all shows
will be locked out. When removed, incoming levels will be combined with those of the active show
on the Rerun Architectural in a highest-takes-precedence (HTP) fashion.
JP6
CF Card initialize - When removed, the memory card is erased at power up. Use with CAUTION!
REMOTE SHOW RECALL PANEL
Remote control of the Rerun Architectural system is accomplished by use of a Preset 10 Architectural
(model PRE10-A) panels. The remote panel provides ten show buttons and twelve indicators (Figure 1).
Multiple remote panels can be connected in a daisy chain manner to the DMX512 input on the Rerun
Architectural.
The remote panel must be configured as a "slave". Remove the jumpers located at JP2 and JP4 to
configure a Preset 10 Architectural as a "slave"(Figure 2). Place the jumper over only one of the pins at
JP2 and JP4 for storage.