Baumer GIM500R Handbuch - Seite 20
Blättern Sie online oder laden Sie pdf Handbuch für Zubehör Baumer GIM500R herunter. Baumer GIM500R 20 Seiten. Inclination sensors
Auch für Baumer GIM500R: Handbuch (29 seiten), Handbuch (13 seiten), Montageanleitung (2 seiten)
4.2 LED activity indicator
Integrated in the sensor housing
LED green
4.2.1
LED activity indicator
Flashing
on
off
LED red
4.2.2
LED activity indicator
Slowly flashing
on
off
LED amber
4.2.3
LED activity indicator
Slowly flashing
on
off
DUO-LED in standard operation
4.2.4
Example for DUO-LED indications in a 2-point teaching operation, min. limit 315°, max. limit 90°.
min.
Position
315°
Baumer_GIM500R_Analog_MA_EN.docx
11.04.18
Activity
Teaching operation
Standard operation
Power off
Activity
Teaching operation
Outside the sensing range
No error
Activity
In teach mode
Teaching operation successful
teach mode off
max.
Position
90°
20/20
Description
See teaching operation
Sensor position within the
sensing range
Description
See teaching operation
Inclination sensor position outside
the sensing range
Description
Inclination sensor is ready for the
teaching operation.
Value was adopted by the
inclination sensor
Inclination sensor is in operational
mode
min.
Position
315°
Villingen-Schwenningen, Germany
max.
Position
90°
Baumer IVO GmbH & Co. KG