3
|
Description
Teaching the analog measurement field
Instruction:
a) Press the teach button briefly.
ü
Green and yellow LEDs light up (teach button is active). If the LEDs do not light up, start
the sensor again.
b) Keep the teach button pressed for 4 seconds.
ü
Yellow LED blinks with 2 Hz.
c) Place the measurement object on position 1 (P1) and briefly press the teach button within
60 seconds.
ü
The min. limit of the analog measurement range has been taught in (distance at which
the min. voltage or min. current is displayed).
d) Place the measurement object on P2 and briefly press the teach button within 60 seconds.
ü
The max. limit of the analog measurement range has been taught in (distance at which
the max. voltage or max. current is displayed).
Result:
ü
Teach-in OK: Green and yellow LEDs light up briefly. Afterwards, the sensor returns to oper-
ating mode.
ü
Teach-in not OK: Green and yellow LEDs blink simultaneously with 8 Hz.
NOTICE
The characteristic curve of the analog output can be inverted by the teaching process (negative
gradient). To do this, teach in the maximum distance for P1 and the minimum distance for P2.
Ill. 3: Analog measurement field (inverted)
12
Sdc
P2
ZP
Operating Manual
Sde
P1
Analog
measurement field
Baumer
OM20/OM30 | V1