Baumer G0LMH Handbuch - Seite 12

Blättern Sie online oder laden Sie pdf Handbuch für Medienkonverter Baumer G0LMH herunter. Baumer G0LMH 26 Seiten. Absolute encoder profibus-dpv0 (with bus cover and ssi coupler)

Baumer G0LMH Handbuch
Important note for multiturn encoder operation
This encoder supports „Endless Operation" automatically if required.
Thus, there are no special requirements for the encoder parameters "total measuring range" and "measuring
units per revolution" to stand in a certain ratio.
With endless operation active, the encoder shaft must not rotate when the encoder is not powered. In
those cases where powerless motion cannot be avoided, the encoder has to be referenced (presetted) after
each power-up. With Endless Operation inactive, the encoder shaft may rotate unlimited when encoder not
powered.
How to determine if „Endless Operation" is in use:
 Multiply the encoder's „max. possible revolutions" (depending on encoder 16 bit = 65536 or 13 bit =
8192) by your chosen parameter „measuring units per revolution".
 Divide this value by your chosen „total measuring range".
 If there is a division remainder, endless operation is in use.
Example for parameters without endless operation:
Maximum possible revolutions
Measuring units per revolution
Total measuring range
Calculation:
Example for parameters with endless operation:
Maximum possible revolutions
Measuring units per revolution
Total measuring range
Calculation:
Baumer_ProfibusDPV0_BIDE_MA_EN.docx
11.19
65536
(16 bit multiturn)
3600
29.491.200
(8192 x 3600)
65536 x 3600 / 29.491.200 = 8 (no remainder)
65536
(16 bit multiturn)
3600
100.000
65536 x 3600 / 100.000 = 2359 remainder 29600
12/26
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany