Baumer GBAMH Handbuch - Seite 8

Blättern Sie online oder laden Sie pdf Handbuch für Medienkonverter Baumer GBAMH herunter. Baumer GBAMH 26 Seiten. Absolute encoders with profinet interface with bus cover
Auch für Baumer GBAMH: Handbuch (24 seiten)

Baumer GBAMH Handbuch

5. Encoder operating parameters

Description of operating parameters
Parameter
Sense of rotation
Resolution
Measurement range Total resolution = number of steps per revolution x number of revolutions,
Preset value
Operating parameter values
Parameter
Sense of rotation
Resolution
Measurement range 1 to 67108864 (2
Preset value
Baumer_ProfibusDPV0_BIDE_MA_EN.docx
11.19
Significance
Behaviour of the output code depending on the sense of rotation of the shaft seen
looking at the flange
CW = Increasing values with clockwise rotation
CCW = Increasing values with counterclockwise rotation
Number of steps per revolution, input in integral steps
input in integral steps
A certain output value is assigned to the current position value (referencing)
Value range
CW/CCW
1 to 4096 – magtivo
1 to 8192 – multivo
1 to 262144 – activo/multivoPlus
) – magtivo
26
) – multivo
29
1 to 536870912 (2
31
1 to 2147483648 (2
)
– activo/multivoPlus
0 to (measurement range - 1 step)
Default setting
CW
4096
8192
262144
67108864
536870912
2147483648
0
8/26
Data type
Octet string
Unsigned 32
Unsigned 32
Unsigned 32
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany