3. Encoder operating modes

3.1. Poll Mode

In Poll Mode the encoder will transmit upon request of another user. The data transferred may optionally
comprise position data or an additional warnflag and alarmflag.

3.2. Change of status Mode (COS)

The encoder will transmit position data without being requested by another user if the actual process value
has changed by a certain value (adjustable COS-Delta).

3.3. Cyclic Mode

The encoder will transmit position data without being requested by another user upon expiry of a
programmable time interval (adjustable 1...65535 ms).

4. Encoder operating parameters

Significance of operating parameters
Parameter
Significance
Sense of
Behaviour of the output code
rotation
depending on the sense of
rotation of the shaft when
looking at the flange
CW = increasing values with
clockwise rotation
CCW = increasing values with
counterclockwise rotation
Resolution
Number of steps per
revolution, input in integral
steps
Measurement
Total resolution = number of
range
steps per revolution x number
(total
of revolutions
resolution) *
Preset value
A certain output value is
assigned to the current
position value (referencing)
* With singleturn encoders the measurement range equals the resolution
Manual_GXP8W_EN.doc
04.05.11
Value range
decimal
hex
CW = 0
CW = 0h
CCW = 1
CCW = 1h
1..8192
1..2000h
1..536870912
1..20000000h
0.. selected total resolution -1
5/13
Default
setting
Bit
(decimal)
CW = 0
1..13
8192
1..29
536870912
0
Baumer IVO GmbH & Co. KG