Baumer HMG 10 PROFINET Installations- und Betriebsanleitung - Seite 11
Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für Medienkonverter Baumer HMG 10 PROFINET herunter. Baumer HMG 10 PROFINET 32 Seiten. Absolute encoder with magnetic sensing
4.3
Mounting to drive shaft
4.3.1
Version with blind hollow shaft
)
Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error, see
page
High runout of the drive shaft can cause vibrations, which can shorten the lifeti-
me of the encoder�
» Lubricate drive shaft!
)
Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
ød (mm)
L1 (mm)
16
53
h6
20
35
h6
i
The encoder must be mounted with cable connection facing downward and not
exposed to water�
MB248EN - 11171699, 17A2, Baumer_HMG10-PROFINET_II_EN
12�
L2 (mm)
52 (40-52)
34 (25-34)
7b
5
10b
10c
10a
10e
10d
MOUNTING / MOUNTING TO DRIVE SHAFT
7b
10c 10b
10b
9
10c
1�6x8 mm
L1
L2
DIN 332-D
M6x16 mm
16 mm
17 mm
7a
11b
11a
Mt = 6 Nm
10 mm
section 4.5,
TX 20
2
3
5 mm
8/29