Baumer Hübner
5
Installation
NOTICE
Equipment damage due to mechanical shock
Strong vibration may lead to overload by constraining force.
a) Never apply force. If properly assembled, everything fits smoothly together.
b) Use only suitable tools for disassembly (see chapter on disassembly).
NOTICE
Equipment damage by adhering liquids
Sticky liquids may damage sensing unit and ball bearings. Disassembling a device which is
stuck to the axis can lead to destruction.
a) Do not use adhesive liquids to fasten the device.
5.1
Mounting with EURO flange B10
5.1.1
Attach coupling onto encoder shaft
INFO
Baumer recommends to use the Baumer Hübner K 35 spring disc coupling to connect the rotary
encoder and the drive shaft of the following device. The Baumer Hübner K 35 spring disc cou-
pling can be pushed onto the drive shaft without axial pressure.
1
Ill. 3: Attach coupling onto encoder shaft
1
Coupling
Tools
2.5 mm
n
V1 | PMG10 & PMG10P DeviceNet
Operating Manual
Installation
|
5
11