Comanex 070 00923 Betriebshandbuch - Seite 4
Blättern Sie online oder laden Sie pdf Betriebshandbuch für Heizgerät Comanex 070 00923 herunter. Comanex 070 00923 6 Seiten. Sdc/ddc heater
Comanex
Electric fan features :
Built-in electronics to reduce components
Low power consumption
Electronically commutated external rotor motor
Electronic protection against reverse polarity, locked rotor and overloading
(inherently safe)
Metal fan housing
Precision ball bearings
Low noise level : 50 dB(A) at 24V ; lower for lower tensions.
Service life L
Working temperature range : -20° C to +70° C
Protection grid
2. OPERATING PRINCIPLE
The heater has two parts, a heat exchanger and a fan.
The gas is forced through the heat exchanger by the fan. The heat exchanger consists of
a finned tube which is spiral-wound to provide a large exchange surface. Hot water is
circulated through the coiled tube.
3. OPERATION
3.1. Precautionary remarks
The heat output increases with the flow and temperature of the hot water and the
pressure inside the chamber.
The hot water flow rate in the heat exchanger should be at least 8 litres per minute, and
increasing it up to 40 l/min will increase the heat output.
The water temperature should be at least 40° C for B ells and 60° C for DDCs.
Increasing the flow rate to more than 12 l/min will only increase the heat output slightly,
whereas increasing the water temperature will increase it much more.
The greater the depth, the more effective the heat exchanges.
The exchanger is supplied with water though 3/4" BSP nipples. To obtain the best
performances, the water flow and gas flow should be in reverse directions.
See chapter 6. Dimensions
: 80 000 hours at 40° C
10
ref. : 070 00923
Page 4/6