3
Connecting
This chapter will explain how the contacts are assigned and give you
some examples of connection.
Under chapters 3.1 to 3.6, you will find actual tips and technical data
for the various connections.
Assignment Relay outputs
Connecting assignment
Relay outputs and electronic outputs
Terminal
10
11
12
13
14
15
Function
1
Supply voltage (-)
2
Supply voltage (+)
3
Relay output / Output P1
4
Relay output / Output P1
5
Relay output / Output P2
6
Relay output / Output P2
7
Signal input A (Count)
8
Signal input B (Tacho)
9
Control input 1 (Tacho Hold)
Control input 2 (Programming disabled)
Control input 3 (Batch counter reset)
Sensor supply (+)
Sensor supply (–)
Option RS485 (T,R-)
Option RS485 (T,R+)
www.baumer.com
Electronic outputs
TA134