Baud rate
0 * 4800 Baud
1
2400 Baud
2
1200 Baud
3
600 Baud
Parity
0 * Even Parity
1
Odd Parity
2
No Parity
Stop bits
0 * 1 Stop bit
1
2 Stop bits
Address
0 * from
99
to
The dash line indicates the end of the third programming field.
By pushing
or
of the first programming field. Programming can be shut down at any
time by pushing the keys
6
Technical data
Technical data - electrical ratings
Voltage supply
Leistungsaufnahme
Sensorversorgung
Display
Number of digits
Digit height
Unit displayed
Function
Measuring principle
Signal inputs
Input logic
Control inputs
Control functions
Counting frequency
Tacho frequency
Scaling factor
Data memory
Outputs electronic
Outputs relay
www.baumer.com
The programming lines 51-54 are
only displayed for models with
interface
, the instrument switches back to the beginning
and
simultaneously.
24/48 VAC ±10 % (50/60 Hz)
85...265 VAC (50/60 Hz)
12...30 VDC, 5 % RW
5 VA, 5 W
24/48 VAC: 10...26 VDC / 60 mA
85...265 VAC: 24 VDC ±20 % / 100 mA
12...30 VDC: 9...28 VDC / 100 mA
LCD, 7-segment display,
2-lines, backlit
6-digits
7 mm (count)
4 mm (preset)
1/s, 1/min, 1/h programmable
Tachometer
Period duration measurement
Comparator inputs
NPN / PNP
3 programmable
Stop, Hold, Print
3 Hz, 25 Hz, 10 kHz programmable
25 Hz, 40 kHz programmable
0.0001...9999.99
>10 years in EEPROM
Optocoupler
Normally open or closed, programmable