Baumer TDP 0,2LT-6 Installations- und Betriebsanleitung - Seite 28
Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für Messgeräte Baumer TDP 0,2LT-6 herunter. Baumer TDP 0,2LT-6 32 Seiten. Tachogenerator with integrated encoder
11
Technical data
11
Technical data
11.1
Technical data - electrical ratings
Interference immunity:
•
Emitted interference:
•
Approvals:
•
11.2
Technical data - electrical ratings (tachogenerator)
Reversal tolerance:
•
Linearity tolerance:
•
Temperature coefficient:
•
Isolation class:
•
Calibration tolerance:
•
Climatic test:
•
TDP 0,2 + OG 9
Performance:
•
Armature-circuit time-constant (τ
•
Open-circuit voltage:
•
TDPZ 0,2 + OG 9
Performance:
•
Armature-circuit time-constant (τ
•
Open-circuit voltage:
•
11.3
Technical data - electrical ratings (encoder)
Voltage supply:
•
Consumption w/o load:
•
Pulses per revolution:
•
Phase shift:
•
Scan ratio:
•
Reference signal:
•
Sensing method:
•
Output frequency:
•
Output signals:
•
Output stages:
•
11.4
Technical data - mechanical design
Dimensions (flange):
•
Shaft type:
•
Shaft loading:
•
Flange:
•
Protection DIN EN 60529:
•
Speed (n):
•
Torque:
•
Materials:
•
Operating temperature:
•
Resistance:
•
Connection:
•
25
):
A
):
A
Baumer_TDP02-OG9-TDPZ02-OG9_II_DE-EN (14A1)
EN 61000-6-2:2005
EN 61000-6-3:2007/A1:2011
CE, RoHS
≤0.1%
≤0.15%
±0.05%/K
B
±1 %
Humid heat, constant (IEC 60068-2-3, Ca)
12 W (speed >3000 rpm)
<75 µs
10...150 mV per rpm
2x 3 W (speed >3000 rpm)
<40 µs
20...100 mV per rpm
5 VDC ±5 % / 9...26 VDC
9...30 VDC
≤100 mA
1...1250
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz
K1, K2, K0 + inverted
TTL/RS422 / HTL-P (power linedriver)
ø115 mm
ø11 mm solid shaft (Option: ø14 mm solid shaft)
≤60 N axial, ≤80 N radial
EURO flange B10
IP 55 (Option: IP 56)
≤10000 rpm
1.5 Ncm
Housing: aluminium die-cast, Shaft: stainless steel
-30...+100°C
IEC 60068-2-6:2007:
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27:2008:
Shock 100 g, 6 ms
2x terminal box
MB079.3 - 11130053