Baumer Hubner Berlin TDP0,2LS-4 Installations- und Betriebsanleitung - Seite 28

Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für Tragbarer Generator Baumer Hubner Berlin TDP0,2LS-4 herunter. Baumer Hubner Berlin TDP0,2LS-4 32 Seiten. Tachogenerator with integrated centrifugal switch
Auch für Baumer Hubner Berlin TDP0,2LS-4: Installations- und Betriebsanleitung (28 seiten)

Baumer Hubner Berlin TDP0,2LS-4 Installations- und Betriebsanleitung
10

Technical data

10
Technical data
10.1

Technical data - electrical ratings

Interference immunity:
Emitted interference:
Approval:
10.2

Technical data - electrical ratings (tachogenerator)

Reversal tolerance:
Linearity tolerance:
Temperature coefficient:
Isolation class:
Calibration tolerance:
Climatic test:
TDP 0,2 + FSL
Performance:
Armature-circuit time-constant (τ
Open-circuit voltage:
TDPZ 0,2 + FSL
Performance:
Armature-circuit time-constant (τ
Open-circuit voltage:
10.3

Technical data - electrical ratings (centrifugal switch)

Switching accuracy:
Switching deviation cw-ccw rotation: ≤3 %
Switching hysteresis:
Switching outputs:
Output switching capacity:
10.4

Technical data - mechanical design

Size (flange):
Shaft type:
Shaft loading:
Flange:
Protection DIN EN 60529:
Speed (n):
Range of switching speed (ns):
Torque:
Materials:
Operating temperature:
Resistance:
Connection:
TDP 0,2 + FSL
Rotor moment of inertia:
Weight approx.:
TDPZ 0,2 + FSL
Rotor moment of inertia:
Weight approx.:
25
EN 61000-6-2:2005
EN 61000-6-3:2007/A1:2011
CE
≤0.1 %
≤0.15 %
±0.05 %/K
B
±1 %
Humid heat, constant (IEC 60068-2-3, Ca)
12 W (speed >3000 rpm)
):
<75 µs
A
10...150 mV per rpm
2x 3 W (speed >3000 rpm)
):
<40 µs
A
20...100 mV per rpm
±4 % (Δn = 2 rpm/s); ≥ +20 % (Δn = 1500 rpm/s)
~40 % of switching speed
1 output, speed control
≤6 A / 230 VAC; ≤1 A / 125 VDC
ø115 mm
ø11 mm solid shaft (Option: ø14 mm solid shaft)
≤60 N axial; ≤80 N radial
EURO flange B10
IP55 (option: IP56)
≤1.25 · ns
850...4500 rpm (Δn = 2 rpm/s)
1.5 Ncm
Housing: aluminium die-cast; Shaft: stainless steel
-30...+130 °C
IEC 60068-2-6:2007: Vibration 5 g, 10-2000 Hz
IEC 60068-2-27:2008: Shock 150 g, 1 ms
2x terminal box
1.4 kgcm²
3.1 kg
1.5 kgcm²
3.5 kg
Baumer_TDP02-FSL-TDPZ02-FSL_II_DE-EN (15A3)
MB079.1 - 11115288