Baumer EXG50 Benutzerhandbuch - Seite 23
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Digitalkamera Baumer EXG50 herunter. Baumer EXG50 42 Seiten. Gigabit ethernet
Auch für Baumer EXG50: Benutzerhandbuch (42 seiten)
4.5.3. Defectpixellist
As stated previously, this list is determined within the production process of Baumer cam-
eras and stored in the factory settings (see 4.8.1.).
Additional hot or cold pixels can develop during the lifecycle of a camera. In this case
Baumer offers the possibility of adding their coordinates to the defectpixellist. The user
can determine the coordinates
defect pixel list is stored in a user set (see 4.8.), pixel correction is executed for all coor-
dinates on the defectpixellist.
4.6. Process Interface
4.6.1. IO Circuits
Output high active
Camera
Customer Device
IO Power V CC
I OUT
R L
IO GND
*)
Position in relation to Full Frame Format.
of the affected pixels and add them to the list. Once the
*)
Output low active
Camera
Customer Device
IO Power V CC
R L
I OUT
IO GND
Input
Customer Device
Camera
DRV
IO GND
23