Baumer SXC80 Benutzerhandbuch - Seite 20
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Digitalkamera Baumer SXC80 herunter. Baumer SXC80 48 Seiten. Sxc series
cameralink cameras with truesense imaging
sensors
Auch für Baumer SXC80: Schnellstart-Handbuch (2 seiten)
Figure 12 ►
Temperature measure-
ment points of Baumer
SXC cameras.
20
Environmental Requirements
6.5.
6.5.1. Temperature and Humidity Range
Storage temperature
Operating temperature*
Housing temperature
**)***)
* For environmental temperatures ranging from (value A) to (value B), please pay atten-
tion to the max. housing temperature. The values are listed in the table below:
Caution
Provide adequate dissipation of heat, to ensure that the temperature does
not exceed +60°C (+140°F).
The surface of the camera may be hot during operation and immediately
after use. Be careful when handling the camera and avoid contact over a
longer period.
Storage and Operating Humidity
6.5.2. Heat Transmission
It is very important to provide adequate dissipation of heat, to ensure that the housing
temperature does not reach or exceed +60°C (+140°F). As there are numerous possibili-
ties for installation, Baumer do not specifiy a specific method for proper heat dissipation,
but suggest the following principles:
▪
operate the cameras only in mounted condition
▪
mounting in combination with forced convection may provide proper heat dissipation
*)
Please refer to the respective data sheet.
**)
Measured at temperature measurement point (T).
***)
Housing temperature is limited by sensor specifications.
*)
Temperature
-10°C ... +70°C ( +14°F ... +158°F)
+5°C ... +60°C (+41°F ... +140°F)
max. +60°C (+140°F)
Humidity
T
10% ... 90%
Non-condensing