Sensitivity
Manual SCATEC-2
Version 2021-09
FLDK 110x1003/Sxx; FLDK 110x1303/Sxx :
Edges from 0.20 mm thickness and greater are detected
FLDK 110x1005/Sxx and FLDK 110x1006/Sxx
Edges from 0.25 mm thickness and greater are detected
Sensitivity is dependant on distance and speed
Typical sensitivity characteristics see figure below
Scatec-2 FLDK 110x1003/Sxx
1.4
typical sensitivity characteristics
1.2
1.0
0.8
m axim um
0.6
sensitivity
0.4
0.2
0.0
0
5
10
15
20
Working distance d [mm]
How to read the graphics:
An edge with thickness k (*) at distance d can be detected when in the
graphics k is above the curve at the corresponding distance d .
(*) Test object: cleanly cut white paper or cardboard
29
www.baumer.com
Sensitivity
reduced
sensitivity
v = 1 ... 2 m /s
25
30
35
40
45
Baumer Electric AG
Frauenfeld, Switzerland
v = 2 m /s
v = 1 m /s
50