DIP-switch settings:
The effects of the various DIP-switch settings are
described in Section 9: Instructions for use below
Do remount the cover after having set the
DIP-switch to avoid intrusion of dust
FLDK 110x1003/Sxx
FLDK 110x1005/Sxx
DIP-
Parameter
switch
Output pulse
1 / 2
length
False pulse
3
suppression
Sensitivity
4
italic: Factory settings
Manual SCATEC-2
Version 2021-09
Setting
Value
off / off
5 ms
off / on
10 ms
on / off
15 ms
on / on
20 ms
off
inactive
on
active
off
maximum
on
reduced
www.baumer.com
on