Baumer NE134 Betriebsanleitung - Seite 37

Blättern Sie online oder laden Sie pdf Betriebsanleitung für Kassenschalter Baumer NE134 herunter. Baumer NE134 44 Seiten. Electronic preset counter

Line 26
Line 27
Line 30
Line 31
Line 32
Line 33
Line 34
Indication of measuring unit on display
0 * Without measuring unit
1
m
2
dm
3
cm
4
mm
5
L
Assignment of lower display
The upper display always indicates the current value.
0
Without lower display
1
P1 - Preset
2 * P2 - Preset
3
SC - Start count
4
tot - Totalizer
5
b - Batch counter
6
SF - Scaling factor
Counting mode main counter and totalizer
0 * Counting input track A, reversal track B
1
Subtraction track A adding and track B subtracting (A-B)
2
Totaling track A adding and track B adding (A+B)
3
Track A 90° track B single evaluation
4
Track A 90° track B double evaluation
5
Track A 90° track B quadruple evaluation
In case of the counting mode „track A 90° track B" , the frequency of
track A and B (Line 31 and 32) must be adjusted to 10 kHz.
Frequency main counter track A
0 * 10 kHz
1
25 Hz
2
3 Hz
Frequency main counter track B
0 * 10 kHz
1
25 Hz
2
3 Hz
Input logic and operating thresholds of signal inputs
0 * PNP Operating threshold 6 V
1
NPN Operating threshold 6 V, or for Namur w/o ex. protection
2
PNP Operating threshold 3 V
3
NPN Operating threshold 3 V
Function control input 1 (contact 9)
0 * PC - Main counter - Reset static
1
PC - Main counter - Reset edge-triggered
2
PC - Main counter - Stop
3
Hold
4
Programming disabled
5
Keylock
6
Print (principally, 30 ms minimum pulse duration)
7
Main counter-outputs ON
8
Main counter-outputs OFF
www.baumer.com
NE134