Suitable encoder PTB-version

10. Suitable encoder

Technical Data
Model
RPM value
Supply Voltage
Input signals
Signal output
Resolution
Current consumption
Ambient temperature
Storage temperature
Protection to
Shaft w/o seal
Shaft with seal
Relative humidity
Endurance
Vibration
Schock
Starting torque
w/o seal (IP54)
with seal (IP65)
Interference immunity
Emitted interference
Shaft loading
Inertia torque
Housing material
Weight

Order designation

GPI0W.
NE215
Incremental Encoder
-1
10.000 min
10...30 VDC, with reverse voltage protection
Push-pull, outp., short-circuit-protect.
Kanal A, B, N
Up to 500 Impuls
Max. 60 mA (w/o load) for 24 VDC
-20...+70 °C
-20...+100 °C
IP 54
IP 65
Max. 95 %, not condensing
IEC 68 part 2-6 ≤100 m/s
IEC 68 part 2-27 ≤1000 m/s
≤0,010 Nm
≤0,015 Nm
EN 50082-2
EN 61000-4 - 2 to 4 Serverity grade 3
EN 50081-2
Axial < 20 N, radial < 40 N
-6
2
1,45 x 10
kgm
Aluminium
Ca. 250 g
Order
Flange / Shaft
0
Clamping flange / 10 mm, mounting M3
1
Clamping flange / 10 mm, mounting M4
5
Servo flange / 6 mm, mounting M4
Voltage / Signals
10
10...30 VDC push-pull output A 90° B +0
Connection
12
Cable 2 m axial, Pg9
14
Cable 5 m axial, Pg9
16
Cable 10 m axial, Pg9
22
Cable 2 m radial, Pg9
24
Cable 5 m radial, Pg9
26
Cable 10 m radial, Pg9
Impuls
39
50 Imp./rev.
15
500 Imp./rev.
2
/ 16-2000 Hz
2
4 ms
37