Dover Hydro Xtreme Service-Handbuch

Blättern Sie online oder laden Sie pdf Service-Handbuch für Water Pump Dover Hydro Xtreme herunter. Dover Hydro Xtreme 4 Seiten. Diaphragm pump

Dover Hydro Xtreme Service-Handbuch
Safety Precautions
WARNING! Please read precautions thoroughly before operation. Meet all applicable local codes and regulations.
protective clothing and eyewear when dispensing chemicals or other materials or when working in the
WEAR
vicinity of all chemicals, filling or emptying equipment, or changing metering tips.
observe safety and handling instructions of the chemical manufacturer.
direct discharge away from you or other persons or into approved containers.
dispense cleaners and chemicals in accordance with manufacturer's instructions.
ALWAYS
exercise CAUTION when maintaining your equipment.
reassemble equipment according to instruction procedures. Be sure all components are firmly screwed or
latched into position.
equipment clean to maintain proper operation.
KEEP
To properly maintain your Hydro Xtreme diaphragm pump, you must service it after every 10,000 hours of operation. Hydro
Systems offers a comprehensive service kit with which you can refurbish your Hydro Xtreme pump. NOTE! The HYD710 style
pump and parts kit are used as the examples in this procedure, but if you have a chlorine dioxide pump the steps to perform
are the same even if the appearance of the pump and service parts are slightly different.
Hydro
Xtreme
HYD710
Style: For
Hydrogen
Peroxide
& Sodium
Hyper-
chlorate
Hydro
Xtreme
HYD712
Style: For
Chlorine
Dioxide
Safety First! Before you start any maintenance to the pump, make sure that you follow the necessary safety precau-
tions listed above and as outlined in the Hydro Xtreme Quick Start Guide that came with the pump.
Step 1: Rinse pump and tubes with clean water
Run clean water through your unit in order to remove any
residual chemical that exists in the pump lines.
Step 2: Unplug pump and turn off water supply
Unplug the power cord of your Hydro Xtreme pump, and turn
off the water flow into which the chemical is being injected.
Thank you for purchasing Hydro Systems' products!
Please use this equipment carefully and observe all warnings and cautions.
service guide
Hydro Xtreme Diaphragm Pump
HYD10098984 - Hydro Xtreme Service Kit, HYD710 style
HYD10098997 - Hydro Xtreme Service Kit, HYD712 style
Step 1:
Rinse
Pump
and
Tubes
Step 2:
Unplug
Pump,
Turn off
Water