Hydraulic Drive
The pump may also be driven hydraulically. Hydraulic motors
need to be well supported with their shafts parallel to the
pump shaft in all respects. Blackmer provides an optional
close-coupled hydraulic motor adapter. The adapter provides
for straight alignment of a hydraulic motor drive through a
solid coupling connected to a straight key shaft. This coupling
connection requires grease lubrication every three months at
minimum. Refer to the "Lubrication" section of this manual.
Figure 3
PUMP ROTATION
NOTICE:
Confirm correct pump rotation by checking the pump
rotation arrows respective to pump driver rotation.
INSTALLATION
Hydraulic Drive
201-D00
TO CHANGE PUMP ROTATION
The TXD1200 series pump models are equipped with a
double ended rotor and shaft, enabling them to be driven from
either shaft end. To change rotation, rotate the pump 180
degrees so that the opposite shaft becomes the driven shaft.
The shaft protector (186) MUST be mounted over the non-
driven shaft end.
Operation without shaft protector can
cause serious personal injury, major
property damage, or death.
Do not operate
without guard
in place