SECTION 7B
REASSEMBLY HINTS & TIPS
ASSEMBLY:
Upon performing applicable maintenance to the air distrib-
ution system, the pump can now be reassembled. Please
refer to the disassembly instructions for photos and parts
placement. To reassemble the pump, follow the disassem-
bly instructions in reverse order. Please find the applicable
torque specifications on this page. The following tips will
assist in the assembly process.
To ease in the reassembly process, mark a line from the
liquid chamber to the chamber cover. This will assist
with proper alignment during reassembly.
Apply a small amount of Loctite
power/liquid bolt threads.
If air continually blows out the exhaust in very large
quantities, it is possible that it may be saved by
completely disassembling the valve, cleaning all
components and re-lubricating the valve.
If pump stops running or begins to run slowly, inspect
return spring located at the bottom portion of air valve
for damage.
When installing inlet air or exhaust connections, use
correct porting on the air valve or pump will not run.
(See example below for correct connections).
Air Inlet
MAXIMUM TORQUE SPECIFICATIONS
Description of Part
Inlet Manifold Plate
Combo Manifold Plate
Liquid Chamber
®
242 to the
Air Exhaust
Torque
13.5 N•m [10 ft.-lbs.]
13.5 N•m [10 ft.-lbs.]
13.5 N•m [10 ft.-lbs.]