SECTION 5A
PERFORMANCE CURVES
MODEL T2 METAL TEFLON
Height ..................................279 mm (11.0")
Width ...................................268 mm (10.5")
Depth .....................................184 mm (7.3")
Ship Weight ......Stainless Steel 16.3 kg (36 lbs.)
Hastelloy 18.1 kg (40 lbs.)
Air Inlet.........................................6 mm (
Inlet ............................................25 mm (1")
Outlet..........................................19 mm (
Suction Lift..............................1.8 m Dry (6')
9.5 m Wet (31')
Displacement per
Stroke ............................ .19 l (0.05 gal.)
Max. Flow Rate ................95 lpm (25.0 gpm)
Max. Size Solids ...........................3 mm (
1
Displacement per stroke was calculated at 4.8 bar
(70 psig) air inlet pressure against a 2 bar (30 psig)
head pressure.
Example: To pump 45.4 lpm (12.0 gpm)
against a discharge pressure head of 2.7 bar
(40 psig) requires 4.1 bar (60 psig) and 22.1
Nm
3
/h (13 scfm) air consumption. (See dot on
chart.)
Caution: Do not exceed 8.6 bar (125 psig) air
supply pressure.
SECTION 6
SUCTION LIFT CURVE
Suction lift curves are calibrated for pumps operating at 305 m
(1,000') above sea level. This chart is meant to be a guide only.
There are many variables which can affect your pump's operat-
ing characteristics. The number of intake and discharge
1
")
4
3
")
4
1
1
")
8
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters
will fall in the center of the pump performance curve.
®
-FITTED
elbows, viscosity of pumping fluid, elevation (atmospheric
pressure) and pipe friction loss all affect the amount of suction
lift your pump will attain.