Service Manual
Master Plate Pneumatic O-Ring Seal Replacement
The O-Ring seals ensure leak-proof air utility pass through when the master and tool plates are coupled.
The seals should be inspected periodically for any cuts, damage, or abrasion. If any damage has
occurred to the O-Rings, they must be replaced. The O-Rings are replaced by the following procedure:
1.
the master plate seals. Servicing or maintaining the tool changer without isolating it from pneumatic and
electric power sources may result in electric shock and personal injury. WHILE SERVICE OR
MAINTENANCE WORK SHOULD NEVER BE DONE WITH THE TOOL CHANGER CONNECTED TO
A POWER SOURCE, by way of example, electric shock may result where maintenance or service work
involves the use of metallic tools or other electrical conducting materials, particularly when addressing
the O-Rings.
2. A seal replacement kit (Part No. SLKT-480) is available, see Table.3 on Page 8.
3. Carefully remove the O-Rings without damaging the tool changer surface or O-Ring grooves.
4. Place the new O-Rings in the O-Ring grooves of the master body and press until they are fully seated
(see Fig.4). Lubricate lightly with oil after assembly.
Note: The tool plate does not contain pneumatic O-Ring seals.
MASTER PLATE
ELECTRICAL MODULE
Remove all pneumatic and electric power sources from the tool changer before servicing
6
Fig.4
TC1 TOOL CHANGER
Service Manual
O-RING
6