Amphenol Socapex RJSMLAC 8UG CAPS Hardware-Benutzerhandbuch - Seite 5

Blättern Sie online oder laden Sie pdf Hardware-Benutzerhandbuch für Netzwerk-Router Amphenol Socapex RJSMLAC 8UG CAPS herunter. Amphenol Socapex RJSMLAC 8UG CAPS 13 Seiten. Ip68 rugged unmanaged ethernet switch, amphenol rj-switch

Section 3
Selecting a
Site
CAPS for
unused
connectors
Mounting
RJSMLAC 8UG CAPS UM rev. 1
Amphenol
– 948, Promenade de l'Arve – B.P. 29 – 74311 THYEZ Cedex – France - +33(0)4.50.89.28.00 –
www.rjswitch.com

Installation

As with any electronic device, you should place the switch where it will not be subject to
extreme temperatures, humidity, or electromagnetic interference that exceeds the
RJSMLAC-8UG-CAPS
following requirements:
The ambient temperature should be between -35 to 75 degrees Celsius.
The relative humidity is recommended to be less than 95% percent, non-
condensing.
Surrounding electrical devices should not exceed the electromagnetic field (RFC)
standards for MIL-STD-461E.
The switches are pre-equipped with caps on all ports, including power and Ethernet.
Make sure all connectors are protected with cap or sealed plug to ensure sealing
and prevent from deterioration of the contacts.
The RJSMLAC-8UG-CAPS Ethernet Switch can be fastened to any flat surface by
mounting the box directly. Refer to the mechanical drawings below. Make sure to allow
enough room to route your Ethernet and power cables.
The RJSMLAC-8UG-CAPS weights 1.5 Kg and is mounted via its four 4x4.5 mm holes for
screws.
The external dimensions of the RJSMLAC-8UG-CAPS are given here after.
's profile. Specifically, the site you select should meet the
Page 5 of 13
Last Rev: 27-Jun-13