programming (continued)
Program Mode Menus
Entering the Program Mode password and pressing the Enter key will always move first to Program Mode Menu 2.
Program Mode
Menu 2:
Configuration
Program Menu 2
000
2
Detergent Control
000
2 1
Machine Type
022
00
Detergent Type
03 2 1
00
Pulse Feed
03 2 2
00
Alarm Volume
024
00
Rack Time in Rinse
025
00
Initial Charge
026
00
Program Mode Password
027
00
Demo Mode Menu
028
00
1 = Factory Default
0001
1 = Probe Mode
2 = Probeless Mode
1 = Factory Default
0001
1 = Door
2 = Conveyor
2 = Factory Default
000
2
2 = Powder / Solid
0 = Pulse Feed Off
Probe Mode Only
4 = Factory Default
1 = 1 sec On / 9 sec Off - When above 50% of Set Point
000
4
2 = 1 sec On / 9 sec Off - When above 70% of Set Point
3 = 2 sec On / 6 sec Off - When above 50% of Set Point
4 = 2 sec On / 6 sec Off - When above 80% of Set Point
5 = 4 sec On / 4 sec Off - When above 70% of Set Point
6 = 6 sec On / 4 sec Off - When above 80% of Set Point
7 = 6 sec On / 1 sec Off - When above 90% of Set Point
3 = Factory Default
000
3
0 = Off
1 = Low
2 = Medium
3 = High
Conveyor Only
10 = Factory Default
000
1
0
Enter Time (in Seconds) for Rinse Time of 1 Rack.
Can be set from 0 to 29 seconds.
Probeless Mode Only
1 = Factory Default
0001
1 = Automatic
2 = Manual
123 = Factory Default
000
1
3 2
Press Scroll to change Value
Press Next to move Position
Demo Mode
000
Scroll = Detergent Signal
Next = Rinse Signal
To "Adjustments Menu"
Menu 3 for Probe Mode
Menu 4 for Probless Mode
11