Dover Hydro Connected Total Eclipse Schnellstart-Handbuch - Seite 13

Blättern Sie online oder laden Sie pdf Schnellstart-Handbuch für Controller Dover Hydro Connected Total Eclipse herunter. Dover Hydro Connected Total Eclipse 17 Seiten.

Dover Hydro Connected Total Eclipse Schnellstart-Handbuch
programming (continued)
WARNING! It is imperative that when the installer is programming the washer signals, to allow plenty of time between
triggers to ensure that a product (or group of products) will run for each of its triggers.
Programming Notes:
Only program the product amounts that will actually be triggered by the washer supply signals.
Program A, B, and C amounts for different product amounts within a wash formula, or use the amounts as a lockout by
not programming any B or C amount.
With an 8-product PI products 7 and 8 share the same trigger signals (respectively) as products 3 and 5. By programing
alternating A, B and/or C amounts for product 3 and 7 (or 5 and 8) up to 8 products can be dispensed with only 6 signals.
When using a flush manifold only one product may run at a time, and if
multiple products are triggered simultaneously, they are placed in a queue
to run sequentially
Program Formulas Menu
1) On the INSTALLER MENU menu, move the selection box onto the
PROGRAM FORMULAS menu item and press the Enter key to launch
the PROGRAM FORMULAS menu.
2) On the PROGRAM FORMULAS menu, use the Up / Down Arrows to
indicate the formula to be configured and press the Enter key to launch
the F## <formula name> menu.
Product Settings
1) At the F## <formula name> menu, move the selection box onto the
PRODUCT SETTINGS menu item and press the Enter key to launch the
F## PRODUCTS menu.
2) On the F## PRODUCTS menu, use the Up / Down Arrows to indicate
the first product to be added to the formula and press Enter to launch
the F## P# menu for that product. (F## is the Formula, P# is a Product.)
3) On the F## P# menu move the selection box onto the product
parameter to configure and press the Enter key to launch the input
screen for that value.
4) The F## P# DELAY input screen is where to input a value to delay the
dispensing of any of the programmed amount by 0 to 999 seconds.
5) The F## P#A AMOUNT input screen is where to designate how much
product will be dispensed by the first trigger signal, in ounces or ml.
6) The F## P#B AMOUNT input screen is where to designate how much
product will be dispensed by the second trigger signal, in ounces or ml.
7) The F## P#C AMOUNT input screen is where to designate how much
product will be dispensed by the second trigger signal, in ounces or ml.
8) The Right Arrow can be used to test a product delivery amount when
the selection box is on a product amount menu item (not the Delay).
9) Once this product delivery has been configured press Exit to return to
the F## PRODUCTS menu to select another product for this formula.
F01 P1 DELAY
000 SEC
OK
EXIT
F01 P1A AMOUNT
08.00 OZ
OK
EXIT
Set Product Amounts and Delay
PROGRAM FORMULAS
F01 P1B AMOUNT
00.00 OZ
OK
EXIT

INSTALLER MENU

INSTALLER SERVICE
INIIAL SYSTEM SETUP
PROGRAM FORMULAS
DATA TRANSFER
SET UNITS OF MEASURE
F01 PADS
F02 CURTAINS
F03 TOWELS
F04 BED LINEN
F05 BLANKETS
F06 TABLE LINEN
F01 PADS
PRODUCT SETTINGS
SET DEFAULT WEIGHT
SET COUNT PUMP
SET END TIME OFFSET
EDIT NAME
CLEAR FORMULA
F01 PRODUCTS
P1 PRE-WASH
P2 DETERGENT
P3 LIQUID BLEACH
P4 BLEACH ALTERNAT
P5 SOUR-CONDITIONR
P6 ENZYME LIFT
F01 P1
P1 DELAY
000 SEC
P1A AMOUNT 08.00 OZ
P1B AMOUNT 00.00 OZ
P1C AMOUNT 00.00 OZ
TO TEST
F01 P1C AMOUNT
00.00 OZ
OK
EXIT
13