Follett HCD1400NBT Handbuch - Seite 6

Blättern Sie online oder laden Sie pdf Handbuch für Eiswürfelbereiter Follett HCD1400NBT herunter. Follett HCD1400NBT 8 Seiten. With remote air-cooled condensing unit
Auch für Follett HCD1400NBT: Installationsanleitung Handbuch (17 seiten), Handbuch (8 seiten)

Follett HCD1400NBT Handbuch
Horizon
Chewblet ice icemaker
Front View
Evaporator utility requirements/unit specifications
Models
HCD1000
Shipping weight
180 lbs (68 kg)
Standard electrical
Voltage
115
Phase
1-phase
Hertz
60 cycles
Amps
6 (max.)
Circuit
15 Amps
Cord
7 ft (2 m)
Plug
NEMA 5-15
Evaporator unit operating limits
All models
Air temperature
50 F (10 C)
Water temperature
45 F (7 C)
Potable water pressure
10 psi (69 kpa)
Energy & water consumption*
Models
HCD1000
Electricity per 100 lbs
5.1 kWh
(46 kg) of Ice
Water per 100 lbs
13.6 gal (52 L) 13.2 gal (50 L)
(46 kg) of ice
* 90 F (32 C) air temp & 70 F (21 C) water temp
6
Form# 3815
Side View
21.28" (54 cm)
23.50"
(60 cm)
21.05" (54 cm)
1000 Series –
22.8" (58 cm)
1400 & 1800 Series –
23.77" (60 cm)
HCD1400/HCD1800
190 lbs (86 kg)
115
1-phase
60 cycles
6 (max.)
15 Amps
7 ft (2 m)
NEMA 5-15
Minimum
Maximum
100 F (38 C)
90 F (32 C)
70 psi (483 kpa)
HCD1400
HCD1800
4.8 kWh
4.8 kWh
13.2 gal (50 L)
KaTom Restaurant Supply, Inc.
1000 series, 1400 series or 1800 series
with remote air-cooled condensing unit
Evaporator utility requirements/unit specifications
Ice transport hose connection
L2
G
NEMA 5-15
L1
right angle
6.95"
(18 cm)
1.75" (45 mm)
3/8" OD push-in
min. req'd
water inlet
3/4" MPT drain
Important specification/installation notes:
1. 10 ft (3 m) of ice transport tube and insulation are provided
with Satellite-fill models only. Longer tubes available as an
accessory, at extra cost.
2. In Satellite-fill applications, ice enters through top of ice
storage bin or countertop ice and beverage dispenser. For side
entry, contact factory.
3. Separate icemaker and condensing unit drain lines required for
water-cooled models.
4. Drains should be hard piped and insulated. Maintain at least a
¼" per foot (2 cm per meter) slope away from icemaker.
5. Follett recommends installation of an in-line water filtration
system. See available accessories on page 1.
Follett Corporation
801 Church Lane • Easton, PA 18040, USA
+1 (610) 252-7301 • Fax +1 (610) 250-0696
www.follettice.com
Back View
19.3" (49 cm)
2.53"
(65 mm)
2.5" (64 mm)
15.69" (40 cm)
Follett Europe Polska
Mokry Dwór 26C • 83-021 Wislina, Poland
+48 (58) 785-6140 • Fax +48 (58) 785-6159
www.folletteurope.com
5/8" suction line
for HCD1000 and
HCD1400
7/8" suction line
for HCD1800
3/8" liquid line
2.87
(73 mm)
1.81
(46 mm)