Follett EREF Series Handbuch für Installation, Betrieb und Wartung - Seite 6
Blättern Sie online oder laden Sie pdf Handbuch für Installation, Betrieb und Wartung für Kühlschrank Follett EREF Series herunter. Follett EREF Series 20 Seiten. Undercounter refrigerator
Controller Operation
In normal operation the controller displays cabinet temperatures
in °C. Temperatures are displayed to 1 decimal point.
A snowflake LED displays when the compressor is running.
The controller is pre-programmed with a 4 C set point, which provides a
compressor cut-in at 6 C and cut-out at 4 C. This may not meet
your specific application needs. For example, many pharmaceutical
manufacturers recommend that their refrigerated medications be stored
between 2.2 C and 7.8 C. Instructions for changing the set point are found
below.
Note: Follett presets the EREF4 refrigeration system to hold product
temperature at approximately 4.6 C. If you are storing prepack-
aged food in this unit, the set point should be changed to 2.0 C
with a 2.0 C differential (HY) to maintain food below 4.4 C.
Refer to the chart below for the set point for your application's required temperature range:
Set point
(°C)
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
All set points have a 2 C differential (HY setting on the controller). The 2 C differential means that with a 4 C set point, for
example, the compressor will turn off at 4 C and turn on when it reaches 6 C.
Because refrigerant is present in the evaporator, there can be an additional 0.5 - 0.8 C of downward "drift" in temperature after
the compressor turns off. For example, with a 4 C set point and after the compressor cut-out, the temperature may
momentarily display as low as 3.4 C before beginning to rise again.
To display temperature cut-out
STEP
INPUT
1
Press and release SET
To change temperature cut-out
STEP
INPUT
1
Press and hold SET for 3 seconds
2
Press UP or DOWN arrows to
desired cut-out temperature per
above table
3
Press and release SET
6
EREF Refrigerator
Cut-in/ Cut- out
(°C)
3.0/1.0
4.0/2.0
5.0/3.0
6.0/4.0
7.0/5.0
8.0/6.0
9.0/7.0
10.0/8.0
DISPLAY
Current cut-out temperature will display for approximately
5 seconds. Display will return to current refrigerator temperature.
DISPLAY
Current cut-out temperature displayed and °C will flash.
New cut-out temperature displayed.
New cut-out temperature blinks three times, then current
refrigerator temperature will display.
Fig. 7
Normal display range temperature
(°C)
0.5 - 3.0
1.4 - 4.0
2.5 - 5.0
3.4 - 6.0
4.4 - 7.0
5.3 - 8.0
6.3 - 9.0
7.2 - 10.0
4.0