Follett Symphony REF Series Handbuch für Installation, Betrieb und Wartung - Seite 8
Blättern Sie online oder laden Sie pdf Handbuch für Installation, Betrieb und Wartung für Kühlschrank Follett Symphony REF Series herunter. Follett Symphony REF Series 16 Seiten. Undercounter refrigerator
Latch adjustment
To adjust for proper latch engagement
1. Loosen striker plate mounting screws (Fig. 7.1).
2. Move striker plate up or down as required and tighten screws.
3. Test operation of latch.
To adjust for proper gasket seal
1. Loosen striker depth adjustment screw (Fig. 7.2).
2. Adjust stop in or out and tighten screws.
3. Test operation of latch.
Door gasket replacement
1. Remove existing gasket from mounting track. Verify mounting
track is free of any remaining gasket material.
2. Align new gasket with mounting track and press firmly in place.
3. Open and close door, checking for proper gasket seal without
pinching against refrigerator. Adjust latch and or striker as
necessary for proper door closure.
Slide-out compressor tray
Follett's slide-out compressor tray allows technicians to partially slide
the condensing unit from the refrigerator back without cutting
refrigerant lines.
1. Remove the rear panel (Fig. 8.1)
2. Remove the two screws and spacers securing the condensate
pan, and set the pan aside (Fig. 8.2).
3. Remove the two bolts securing the condensing unit to the
refrigerator base (Fig 8.3).
4. Gently slide the condensing unit out (Fig 8.4).
Note: Do not put undue strain on the refrigerant lines
Wiring diagram
NEUTRAL
L2
WHITE
CONTROLLER
120 VAC
BLACK
ON/OFF
SWITCH
BLACK
HOT
L1
CONDENSING UNIT
WHITE
R1
CAP.
RELAY
START
WHITE
BLUE
RELAY
EVAP.
FAN
C
COMP
OVER
LOAD
BLACK
CK
Note 1
R1
BLUE
RELAY
BLACK
Service
WHITE
ND.
N
Note 1: Highlighted area on wiring diagram
indicates jumper included on refrigerators
with service numbers:
BLACK
Service numbers B50486 to B57373 for
R1
RELAY
model REF5
Service numbers B50479 to B57369 for
BLACK
model REF4-ADA
8
Fig. 7
1
2
Fig. 8
3
2
4