Specifications

Display size
Display dimensions (W x H)
Display resolution
Display type
Display color
Booting time
Backlight
Operating temperature
Operating humidity
Storage temperature and humidity
Operating altitude
Transient protection
Pollution degree
IP rating
Drop test
Power supply
Power consumption (typical)
Battery life
Low battery indication
Fuse
Maximum conductor Size
Dimensions (L x W x H)
Weight
Certifications
NOTE: Refer to user manual for ADPTR-SCT and TL-6000 specifications.
Included in Wire Tracer Kits
AT-6000-R Receiver
AT-6000-T Transmitter
TL-6000 Test Lead and
Accessory Kit
CC-6000 Hard Carrying Case
User Manual
12 - Rechargeable Batteries
(not installed)
3 - Battery Chargers
CT-400 Signal Clamp
12 - 1.5 V AA (IEC R6) Batteries
(not installed)
(charger and batteries are not available to order separately)
AT-6020
Amprobe
| [email protected] | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623)
®
AT-6000-R Receiver
LCD 2.5 in (6.35 cm)
1.45 x 1.93 in (36.72 x 48.96 mm)
240(RGB) x 320 pixels
TFT-LCD (262 K)
True, 16bit/color
< 3 sec
-4 °F to 122 °F (-20 °C to 50 °C)
45%: -4 °F to <50 °F (-20 °C to <10 °C)
95%: 50 °F to <86 °F (10 °C to <30 °C)
75%: 86 °F to <104 °F (30 °C to <40 °C)
45%: 104 °F to 122 °F (40 °C to 50 °C)
IP 52
4 x AA (alkaline or NiMH rechargeable)
110mA
Approx. 16 h
Approx. 7.2 x 2.95 x 1.69 in
(183 x 75 x 43 mm)
Approx. 1.25 lb (0.57 kg)
AT-6020
(Optional)
AT-6030
AT-6000-T Transmitter
LEDs
LEDs
Operating mode LEDs: red
Battery status LEDs: green, yellow, red
< 2 sec
-4 °F to 158 °F (-20 °C to 70 °C), <95% RH
0 to 6561 ft (2000 m)
6.00 kV (1.2/50μS surge)
2
3.28 ft (1 m)
8 x AA (alkaline or NiMH rechargeable)
Hi/Lo mode: 70 mA
Loop mode with Clamp: 90 mA
Consumption without signal transmission:
10 mA
Hi/Lo mode: approx. 25 h
Loop mode: approx. 18 h
1.6 A, 700 V, fast-acting, Ø 6x32mm
Approx. 7.2 x 3.66 x 1.97 in
(183 x 93 x 50 mm)
Approx. 6.18 lb (2.8 kg)
AT-6030
©2018 Amprobe
®
For detailed specifications and ordering go to amprobe.com 6010521 A
CT-400 Signal Clamp
32 °F to 122 °F (0 °C to 50 °C)
95%: 50 °F to <86 °F (10 °C to <30 °C)
75%: 86 °F to <104 °F (30 °C to <40 °C)
45%: 104 °F to <122 °F (40 °C to <50 °C)
IP 40
1.26 in (32 mm)
Approx. 5.9 x 2.75 x 1.18 in
(150 x 70 x 30 mm)
Approx. 0.25 lb (0.114 kg)
7