i) 3. Partially close the zip tie (fig. 24) and, when it is close enough, insert the free end of the plastic
fastener into the hole in the inner flange of the zip tie. Then insert this free end of the clamp also
through the ring of the "V" shaped activation pin located on the valve/pressure reducer (fig. 25).
At this point engage the plastic clamp by inserting the free end into the corresponding groove at
the other end. Pull the free end (and slide the rack accordingly to avoid tension that could activate
the air flow), until the free end reaches a length of 20 cm. long (fig. 27). Cut off and pull the excess
part of the free end of the clamp.
j) Close the zip completely and check through the transparent window that the pressure gauge
needle is in the green section, indicating that the cylinder is fully charged (fig. 26).
k) Insert and hook the seal into the hole corresponding to the end of the zip and into the bag.
l)Once the above operations have been completed, the equipment must be as shown in the
figure below.
7.3. Maintenance and interval of control
Description
Clean and disinfect as
necessary
Visual inspection
Refill cylinder to correct
pressure setting
Functional check as described
in the instructions included
with the maintenance kit
Complete
equipment
Anti-fogging fluid on the inner
surface of the hood visor
Replace sealing elements and
any damaged and / or worn
components
Verify test date on bottle
Bottle
Re-certification according to
applicable national regulations
applicable
Despite the efforts made by D.P.I. in the drafting of this manual, D.P.I. cannot be held responsible for any
consequences resulting from the misinterpretation of this text..
After
Every month
Every year
use
x
x
x
x
Every
every 6 years
x
x
x