Comelit 1256 Technisches Handbuch - Seite 6

Blättern Sie online oder laden Sie pdf Technisches Handbuch für Kontrolleinheit Comelit 1256 herunter. Comelit 1256 8 Seiten. Actuator relay module
Auch für Comelit 1256: Technisches Handbuch (16 seiten)

Comelit 1256 Technisches Handbuch
JP1

E) Activation function on Actuator pushbutton

JP1 as illustrated in Fig. 5
JP1
FIG. 5
JP1
The relay is operated by closing the C.NO. contact in response to a Generic actuator call from an entry phone or video entry
phone (e.g. to activate the following independently, using a specific command: lights, CCTV alarm contacts, driveway gates,
entrances without external units or other devices). The relay closure time can be programmed using a DIP-switch (see
A). The function can be used at all times except when a conversation is in progress from an entry phone or video entry phone
other than your own. All art. 1256 modules set for use with this function are activated simultaneously when the pushbutton on
the internal unit is pressed.

F) Activation function on Actuator with code pushbutton.

The function may NOT be used in Simplebus Kit systems

JP1 as illustrated in Fig. 6
JP1
FIG. 6
The relay is operated by closing the C.NO. contact if the pushbutton pressed on the entry phone or video entry phone has
been programmed (using the hand-held programmer art. 1251/A) to send the actuator call with the code of the actuator in
question (e.g. to activate the following independently, using a specific command: lights, CCTV alarm contacts, driveway gates,
entrances without external units or other devices). The closure time of the relay is fixed at 2 sec. the function can be used at
all times, except when a conversation is in progress from an entry phone or video entry phone other than your own. To set the
user code by means of a DIP-switch, see
DIP switches ON
Relay closure time
* The relay for art. 1256 operates in BISTABLE mode, changing its status at every command; if the power supply is cut off, it
returns to the C.NO. position and remains there, even after the power is restored.
Bistable mode is available for products with a revision index equal to or greater than 003.
DIP switches ON
Enabled codes

System performance and layouts

For further information of system performance and to view installation layouts, click on the type of system that best meets your
needs:
Audio/video kit
for the creation of audio-video systems for individual residences.
Building Kit audio/video system
SBTOP audio/video system
SB1 audio system
for the creation of audio systems for residential complexes.
SB2 audio system
for the creation of audio systems for residential complexes.
6
"addressing
TAB. A programming relay closure time for functions B, C and E
ALL
1
2
*
1''
2''
TAB. B programming code Range for function D
1
2
1 ÷ 30
31 ÷ 60
61 ÷ 90
for the creation of audio-video systems for small apartment blocks.
for the creation of audio-video systems for residential complexes.
JP1
table".
3
4
4''
8''
3
4
91 ÷ 120
121 ÷ 150
5
6
16''
32''
1' 5''
5
6
7
151 ÷ 180
181 ÷ 210
table
7
8
2' 10''
8
211 ÷ 240