Daikin ADEA71A2VEB Benutzerhandbuch - Seite 4

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Klimagerät Daikin ADEA71A2VEB herunter. Daikin ADEA71A2VEB 12 Seiten. Split system air conditioners
Auch für Daikin ADEA71A2VEB: Installationshandbuch (16 seiten)

Daikin ADEA71A2VEB Benutzerhandbuch

4 Before operation

d
f
g
e
a
c
a
Indoor unit
b
Outdoor unit
c

User interface

d
Air inlet
e
Air outlet
f
Refrigerant piping and electric wiring
g
Drain pipe
h
Earth wire to ground outdoor unit to prevent electric
shocks.
CAUTION
Do NOT insert fingers, rods or other objects into the air
inlet or outlet. Do NOT remove the fan guard. When the
fan is rotating at high speed, it will cause injury.
CAUTION
▪ NEVER touch the internal parts of the controller.
▪ Do NOT remove the front panel. Some parts inside are
dangerous to touch and appliance problems may
happen. For checking and adjusting the internal parts,
contact your dealer.
NOTICE
Do NOT wipe the controller operation panel with benzine,
thinner, chemical dust cloth, etc. The panel may get
discoloured or the coating peeled off. If it is heavily dirty,
soak a cloth in water-diluted neutral detergent, squeeze it
well and wipe the panel clean. Wipe it with another dry
cloth.
NOTICE
NEVER press the button of the user interface with a hard,
pointed object. The user interface may be damaged.
NOTICE
NEVER pull or twist the electric wire of the user interface. It
may cause the unit to malfunction.
3.2
Information requirements for fan
coil units
Item
Cooling capacity (sensible)
Cooling capacity (latent)
Heating capacity
Total electric power input
Sound power level (per speed
setting, if applicable)
Contact details:
DAIKIN INDUSTRIES CZECH REPUBLIC s.r.o. U Nové Hospody
1/1155, 301 00 Plzeň Skvrňany, Czech Republic
User reference guide
4
b
h
Symbol
Value
Unit
P
A
kW
rated,c
P
B
kW
rated,c
P
C
kW
rated,h
P
D
kW
elec
L
E
dB
WA
A
ADEA125A
7.83
3.3
User interface
CAUTION
▪ NEVER touch the internal parts of the controller.
▪ Do NOT remove the front panel. Some parts inside are
dangerous to touch and appliance problems may
happen. For checking and adjusting the internal parts,
contact your dealer.
This operation manual will give a non-exhaustive overview of the
main functions of the system.
For more information about the user interface, see the operation
manual of the installed user interface.
4
Before operation
WARNING
This unit contains electrical and hot parts.
WARNING
Before operating the unit, be sure the installation has been
carried out correctly by an installer.
CAUTION
It is not good for your health to expose your body to the air
flow for a long time.
CAUTION
To avoid oxygen deficiency, ventilate the room sufficiently
if equipment with burner is used together with the system.
CAUTION
Do NOT operate the system when using a room
fumigation-type insecticide. Chemicals could collect in the
unit, and endanger the health of people who are
hypersensitive to chemicals.
NOTICE
Be sure to turn on the power 6 hours before operation in
order to have power running to the crankcase heater and
to protect the compressor.
5

Operation

5.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.
For combination with R410A outdoor unit, refer to the following
table:
ARXS35~71
Outdoor temperature
Indoor temperature
Indoor humidity
AZQS71~125
Outdoor temperature
Indoor temperature
B
C
D
E
4.27
13.50
0.35
62
Cooling
Heating
10~46°C DB
–15~18°C WB
14~28°C WB
10~30°C DB
(a)
≤80%
Cooling
Heating
–5~46°C DB
–15~15.5°C WB
14~28°C WB
10~27°C DB
ADEA35~125A2VEB
Split system air conditioners
4P551388-1 – 2018.09