User Manual – AS5x61/AS5x62 Programming
16) For calibrating the T1 and T2 voltages of the OutputDac, turn
and start the calibration. This calibration has to be used after the point 5 to point 15.
17) Additional
Values.
18) To program an AS5262 ( DualDie) Device, redo point 5 to point 17 on page
19) Click
20) Set
further information please read AS5x62 Datasheet.
21) Set
range. For further information please read AS5x62 Datasheet.
22) To program an AS5262(DualDie) Device, redo point 20 and 21 for the Top Device.
23) Two actions can happen at this point.
a. You can confirm that the entered data operates as expected. Go to Step 23.
b. You can go straight to burning the configuration in to the AS5x62. Go to Step 31.
24) During this procedure, DO NOT click on
25) Click
26) Click
27) Check if write/read Chksum is green
28) To program an AS5262(DualDie) Device, redo point 20 and 21 for the Top Device.
29) Click
expected.
30) If satisfied with the results go to Step 31, otherwise, go to Step19.
31) Reset the device. You have to push the reset button on the UART Interface board by hand.
This will reset the programming configuration.
32) Go to Step 4 to repeat procedure to change unacceptable parameters.
www.ams.com
to calculate the programming data with the calibrated DAC
to activate the internal filter. Default setting is no filter. For
to choose between normal airgap range or extended airgap
to check with an oscilloscope if your trimming is what you