The REFERENCE POSITION is the distance from the reference
point to the inside jaws of the gripper after being referenced.
Lip Size
If this parameter is greater than zero, a lip will be added to the
beginning of each sheet. The acceptable range of values are
0.0000" to 50.0000".
Metal Flow
This parameter specifies whether the metal is fed from one side
of the brake and the formed parts comes out of the other
(NORMAL); or if it is fed through the backside of the brake,
(REVERSE). If this parameter is set to NORMAL, the machine
should move to the total sheet length plus the CLEARANCE
DISTANCE when there is a new program. When REVERSE is
selected, it will move to the new CLEARANCE DISTANCE.
Clearance Dist
This parameter determines the point at which the gripper will
move to when a new program is entered or after completion of a
sequence. CLEARANCE DIST plus ACTUAL PART LENGTH
will determine the position of the guide between sequences.
Brake Dwell Dn
BRAKE DWELL DOWN is the time it takes for the brake to move
from the top of the stroke to the bottom of the stroke. The range
of time allowed is 0.001 to 9.999 seconds and can be set to the
nearest millisecond.
Brake Dwell Up
BRAKE DWELL UP is the time necessary for the brake to return
from the bottom to the top of its stroke
NOTE:
If the LOOP ENABLE input is used while the brake is
activated, the LOOP ENABLE input must be reactivated
before the total BRAKE DWELL (down and up) is completed.