4.3 Changing of spare parts

4.3.1 Changing the halogen bulbs

Dr. Mach uses special halogen bulbs as illuminants.
Only original Dr. Mach replacement bulbs may
be used.
The use of other bulbs can lead to a considerable
reduction of the light power and increase in the
thermal load.
To change the bulbs proceed as follows:
• Attention!! Turn off the lamp!
• Loosen three screws 27 at the base frame 01.
• Remove housing lower part 02 by pulling it
downwards.
Attention! If the bulb is changed immediately
after operating the lamp, some parts of the lamp
may be hot.
Do not touch the halogen bulb with naked
hands.
• Draw halogen bulb 11 (22,8-24V/50W) carefully
from its socket.
• Put in the new halogen bulb.
• Mount the housing lower part 02 in reverse order
of dismounting it.
Remark:
The halogen bulbs have a service life of approx.
1000 hours without any deterioration in their
luminosity.

4.3.2 Changing the fuses

Because of the external transformer of the Mach
120 lamps, the necessary fuses must be provided
by the customer.
Pay attention to the instructions from the local
installer.
06.02.2010 / Bak Page 7/19