3

OPERATION

3.1

Control layout

3.1.1
SHE models
SHE4AM02UC
SHE4AM12U
SHE5AM02UC
3.1.2
SHX models
SHX3AM02UC
702_58300000130262_ara_en_b
3.2

Using controls

Wash programs don't have dedicated buttons, but are selected
by scrolling with left ("<") and right (">") scroll buttons.
turning on dishwashers, scroll left or right to the desired wash
program (shown by lit program lights between scroll buttons). To
start the desired program, press the Start button.
3.3
Reset ("Cancel – drain")
To reset, press and hold Start button until Active light goes out
(SHX3AM / SHE4AM) or when display shows "0.01" (SHE5AM) --
for SHX3AM models, open door just enough to expose buttons.
Wait about one minute for dishwasher to stop draining -- with
SHX3AM models, door must be closed for dishwasher to drain.
To reset dishwasher, turn it off after it stops.
3.4

Changing basic settings

Extra Dry feature can be turned on or off and rinse-aid dosage
can be changed using dishwasher controls.
models, End of Cycle tone volume can also be changed.
3.4.1
SHE4AM models
Turn dishwasher on, press and hold ">" button, then press and
hold Start button. Clean and Sanitized lights will be flashing
(Extra Dry mode). When lights are flashing, release buttons.
SHE4AM lights
Clean Sanitized
SHE4AM Extra Dry
SHE4AM Rinse Aid
After
For SHX3AM
Rinse
Agent