AirStage ABYA24GATH Installationshandbuch - Seite 14

Blättern Sie online oder laden Sie pdf Installationshandbuch für Klimagerät AirStage ABYA24GATH herunter. AirStage ABYA24GATH 16 Seiten.

AirStage ABYA24GATH Installationshandbuch
Function details
Function
Function
Setting number
number
00
Filter indicator
11
01
interval
02
00
01
Filter indicator
13
action
02
controller
00
Horizontal swing
24
01
Left half
airfl ow direction
02
Right half
00
Cool air
temperature
30
01
Adjust (1)
trigger
02
Adjust (2)
00
Heat air
01
Adjust (1)
temperature
31
02
Adjust (2)
trigger
03
Adjust (3)
00
Auto restart
40
01
00
Super low
Cool Air
43
Follow the
Prevention
setting on
01
the remote
controller
00
Start/Stop
Emergency
External control
46
01
02
00
Display only
Error report
47
on central
target
01
controller
Follow the
setting on
00
Fan setting
the remote
when cooling
49
controller
thermostat OFF
01
En-13
Default
Details
Default
Adjust the fi lter cleaning interval
notifi cation. If the notifi cation is too early,
Longer
change to setting 01. If the notifi cation is
too late, change to setting 02.
Shorter
Enable
Disable
Enable or disable the fi lter indicator.
Display
Setting 02 is for use with a central remote
only on
controller.
central
remote
Default
Adjust the horizontal swing airfl ow
direction.
(For horizontal swing equipped models)
Default
Adjust the cool air trigger temperature. To
lower the trigger temperature, use setting
01. To raise the trigger temperature, use
setting 02.
Default
Adjust the heat air trigger temperature.
To lower the trigger temperature by 6
degrees C, use setting 01. To lower
the trigger temperature by 4 degrees
C, use setting 02. To raise the trigger
temperature, use setting 03.
Enable or disable automatic system restart
Enable
after a power outage.
* Auto restart is an emergency function such
as for power failure etc. Do not start and
stop the indoor unit by this function in
normal operation.
Be sure to operate by the control unit,
Disable
converter or external input device.
Restrain the cold airfl ow with making
the airfl ow lower when starting heating
operation. To correspond to the ventilation,
set to 01.
Allow an external controller to start or stop
the system, or to perform an emergency
stop.
* If an emergency stop is performed from
an external controller, all refrigerant
systems will be disabled.
stop
* If forced stop is set, indoor unit stops by
the input to the external input terminals,
Forced
and Start/Stop by a remote controller is
stop
restricted.
All
Change the target for reporting errors.
Errors can either be reported in all
locations, or only on the central remote
remote
controller.
When set to 01, the fan stops when the
thermostat is OFF in cooling operation.
Connection of the wired remote controller
(2-wire type or 3-wire type) and switching
its thermistor are necessary.
Stop
7.4.1. Button name and function
OPERATION indicator lamp (Green)
TIMER indicator lamp (Orange)
FILTER indicator lamp (Red)
MANUAL AUTO button
7.4.2. Checking the function settings
Press and hold the "MANUAL AUTO" button on the indoor unit for 3 seconds to check the
function settings. It is necessary to disconnect the power in order to return to normal op-
eration mode.
(1) Indoor unit and refrigerant address indication
Indication pattern
Indicator name
OPERATION indica-
tor lamp (Green)
TIMER indicator lamp (Orange)
Address: tens place (0.5s ON/0.5s OFF)
FILTER indicator lamp (Red)
Address: ones place (0.5s ON/0.5s OFF)
• Indoor unit address example
(Example) ADDRESS : 24
OPERATION
ON
indicator lamp
(Green)
OFF
TIMER
ON
indicator lamp
0.5s 0.5s 0.5s 0.5s
(Orange)
OFF
ON
FILTER
0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s
indicator
OFF
lamp (Red)
• Refrigerant address example
(Example) ADDRESS : 30
OPERATION
ON
indicator lamp
1.0s
(Green)
OFF
ON
TIMER
0.5s 0.5s 0.5s 0.5s 0.5s 0.5s
indicator lamp
OFF
(Orange)
ON
FILTER
indicator lamp
OFF
(Red)
• Setting details
Function number
Item
01
Indoor unit address
02
Refrigeration address
For use with a remote controller, set all rotary switches to 0, and refer to "7.1. Setting the
address" for details.
All switches are set to 0 at the factory.
Indication pattern
Indoor unit address
Refrigerant address
ON
Flash (1.0s ON/1.0s OFF)
1 cycle 12 sec
ON
10 sec
8 sec
1 cycle 12 sec
1.0s
1.0s
1.0s
1.0s
1.0s
1.0s
9 sec
OFF
Setting number
00 to 63
00 to 99