We normally do not see cavitation as much with the desander and desilter pumps because the
rubber cones do not wear as rapidly as steel cones. Volume requirements are closer to 800 to
1000 GPM.
Capacity Limits of Pumps
Capacity limits for pumps listed below do not consider suction line velocity or NPSH calculations
which must be made for every installation.
Capacity Requirements of Equipment in Rig Applications
The chart below lists the normal design requirements when the equipment is new with no wear.
EQUIPMENT
4" CONE
4H (5") CONE
6" CONE
8" CONE
12" CONE
6" MUD HOPPER
3/4" NOZZLE
1" NOZZLE
1 1/2" NOZZLE
2" NOZZLE
MECHANICAL BRAKES
ELECTRIC BRAKES
SWACO DEGASSER
WELCO DEGASSER
BRANDT DG5 DEGASSER
BRANDT DG10 DEGASSER
Long Term Pump and Motor Storage
1. Pump packages should be stored indoors in a clean, dry and protected environment.
2. The storage area is to be free from any vibration and temperature extremes.
3. Motor and pump shafts are to be rotated manually every two months. A record of the rotation
should be made.
4. Grease in the motor and thepump bearings is to be purged at the time of removal from
storage and replaced with an ample supply of fresh grease in each grease cavity.
5. Motor windings should be megged at the time the equipment is placed in storage. At the time
of removal from storage the resistance reading must not have dropped more than 50% from
the initial reading. Any drop below this point necessitates electrical or mechanical drying of
the motor windings. Condensation from hot days and cool nights can fill the motor half full
with water. This is a greater potential problem in damp areas.
6. If the pumps are to be stored outdoors, the pump suction and discharge openings should be
sealed to prevent any water from entering the pump housing. This will prevent rust and corrosion.
Item
No.
Description
Parts Cross Reference Chart
Qty Req
MCM
13
DESIGN VOLUME
45 to 60 GPM
80 GPM
125 GPM
250 GPM
450 to 500 GPM
550 GPM
80 GPM
140 GPM
300 GPM
550 to 600 GPM
40 to 50 GPM
50 to 200 GPM
4000 GPM
7000 GPM
500 GPM
1000 GPM
Mission
Halco
Harrjsburg